BESSY II INSTRUMENTATION TOOL

Search Database
Beamline Map
Beamline List
Stations Map
Stations List
Insertion Devices
back to BESSY II Beamlines & Stations

  List of Beamlines


[printable pdf]

Beamline Source Monochromator Energy Range Polarisation Experimental Station(s) Contact Operated by
Litho-EUV D11  Multilayer  95 eV-95 eV HORIZONTAL  EUV-Scanner  Dr. B. Loechel  HZB 
KMC-1 D11  KMC-1  2000, Unset-12000 eV HORIZONTAL  HIKE
XUV Diffractometer 
Dr. F. Schaefers  HZB 
IRIS D11  n.a.  0.0006 eV-1 eV HORIZONTAL  IR-Ellipsometry
IR-Station 
Dr. U. Schade  HZB 
HE-SGM D21  HE-SGM  200 eV-700 eV HORIZONTAL  n.a.  Dipl.-Ing. A. Lippitz  U Bochum, BAM 
ISISS D41  PGM  80 eV-2000 eV HORIZONTAL  ISISS  Dr. M. Hävecker  Fritz-Haber-Institut der Max-Planck-Gesellschaft 
DXRL-2 D61  direct beam  80 eV-2000 eV HORIZONTAL  DEX-02   Dr. B. Loechel  HZB 
PTB-4
Not available to general users!
D71  1m-NIM-1  3 eV-35 eV HORIZONTAL  n.a.  Prof. Dr. M. Richter  PTB/MLS 
PTB-5
Not available to general users!
D71  1m-NIM-2  3 eV-35 eV HORIZONTAL  n.a.  Dr. R. Thornagel  PTB 
PTB-6
Not available to general users!
D71  direct beam  5000 eV-40000 eV HORIZONTAL  n.a.  Dr. R. Thornagel  PTB 
PTB-7
Not available to general users!
D71  KMC  1700 eV-10000 eV HORIZONTAL  n.a.  Dr M. Krumrey  PTB 
PTB-8
Not available to general users!
D71  PGM  30 eV-1800 eV HORIZONTAL  n.a.  F. Scholze  PTB 
Optics Beamline D81  PGM  20 eV-1300 eV HORIZONTAL  REFLECTROMETER
SurICat 
Dr. F. Senf  HZB 
KMC-2 D92  KMC  5000 eV-14000 eV HORIZONTAL  Diffraction
XANES 
Dr. I. Zizak  HZB 
PGM-3 D111  PGM  20 eV-1900 eV HORIZONTAL / CIRCULAR  n.a.  Dr. T. Kachel  HZB 
THz-Beamline D112  FTIR/VERTEX 70  h*50 GHz-h*4.5 THz HORIZONTAL  THz  Dr. K. Holldack  HZB 
3m-NIM-A D121  3m-NIM  2 eV-40 eV HORIZONTAL  VUV Ellipsometer  Dr. P. Baumgärtel  HZB 
3m-NIM-C D121  3m-NIM  2 eV-10 eV HORIZONTAL  UVIS  Dr. P. Baumgärtel  HZB, Uni Potsdam 
EDR D132  direct beam  5000 eV-40000 eV HORIZONTAL  n.a.  Dr. W. Leitenberger  Uni Potsdam 
TGM-7 D151  TGM  8 eV-120 eV HORIZONTAL  So-Li-AS  Prof. Dr. C. Pettenkofer  HZB 
RGBL D161  PGM  30 eV-1500 eV HORIZONTAL  HIRES  Dr. R. Ovsyannikov  HZB, TU Dresden 
BAMline 7T-WLS-1  KMC  5000 eV-40000 eV HORIZONTAL  BAMline  Dr. H. Riesemeier  BAM/PTB 
mySpot Beamline 7T-WLS-1  KMC / Multilayer  2000 eV-30000 eV HORIZONTAL  mySpot  Dr. I. Zizak  HZB, BAM, MPIKG 
U125-2_SGM U125-2  SGM  29 eV-400 eV HORIZONTAL  HIRES  Dr. C. Schussler-Langeheine  BUS ( Berliner Universitätsverbund Synchrotronstrahlung ) 
U125-2_KMC U125-2  KMC  6000 eV-12000 eV HORIZONTAL  PHARAO  PD Dr. M. Hanke  PDI 
U125-2_NIM U125-2  10m-NIM  4 eV-40 eV HORIZONTAL  UVIS  Dr. P. Baumgärtel  HZB 
7T-MPW-EDDI 7T-MPW  direct beam  10000 eV-150000 eV n.a.  EDDI  Dr. M. Klaus  HZB 
7T-MPW-MagS 7T-MPW  KMC  3500 eV-30000 eV HORIZONTAL  MagS
SAXS 
Dr. R. Feyerherm  HZB 
UE56-2_PGM-1 UE56-2  PGM-1  60 eV-1300 eV HORIZONTAL / VERTICAL / CIRCULAR  n.a.  B. Zada
Dr. W. Mahler 
MPG 
UE56-2_PGM-2 UE56-2  PGM-2  60 eV-1300 eV HORIZONTAL / VERTICAL / CIRCULAR  n.a.  B. Zada
Dr. W. Mahler 
MPG 
DXRL-1 6T-WLS / 0.4T-LFD  direct beam  1500 eV-6000 eV n.a.  DEX-01  Dr. B. Loechel  HZB 
PTB-1
Not available to general users!
U49-1  direct beam  n.a.-n.a. n.a.  n.a.  n.a.  PTB 
PTB-2
Not available to general users!
U49-1  13°  n.a.-n.a. n.a.  n.a.  n.a.  PTB 
PTB-3
Not available to general users!
U49-1  PGM  20 eV-1900 eV n.a.  n.a.  n.a.  PTB 
UE49_PGM a/b UE49  PGM  100 eV-1800 eV VARIABLE  SMART
SPEEM 
Dr. F. C. Kronast  HZB 
UE52_SGM UE52  SGM  90 eV-1500 eV VARIABLE  HIRES
POLARIMETER 
Dr. R. Könnecke  HZB 
UE52_PGM UE52  PGM  85 eV-1600 eV VARIABLE  n.a.  Dr. R. Ovsyannikov  U Würzburg 
UE46_PGM-1 UE46  PGM  121 eV-1700 eV LINEAR ANY ANGLE / CIRCULAR  7T High-Field Endstation
XUV Diffractometer 
Dr. E. Weschke  HZB 
UE56-1_PGM-A UE56-1  PGM  60 eV-1300 eV LINEAR HORIZONTAL VERTICAL / CIRCULAR  Femto-s-Pump-Probe
POLARIMETER 
Dr. T. Kachel  HZB 
UE56-1_PGM-B UE56-1  PGM  60 eV-1300 eV LINEAR HORIZONTAL VERTICAL / CIRCULAR  n.a.  Dr. T. Kachel  HZB 
UE56-1_ZP UE56-1  ZP-mono  715 eV-861 eV VARIABLE  n.a.  Dr. T. Kachel  HZB 
UE56-1_SGM UE56-1  SGM  60 eV-1500 eV HORIZONTAL / VERTICAL / CIRCULAR  n.a.  Dr. S. Cramm  Forschungszentrum Juelich 
U41-TXM U41  SGM a  250 eV-600 eV HORIZONTAL  XM  Dr. P. Guttmann  HZB 
U41-STXM U41  SGM b  250 eV-600 eV HORIZONTAL  n.a.  Dr. P. Guttmann  HZB 
U41_PGM U41  PGM  170 eV-1800 eV HORIZONTAL  LIQUIDROME
Liquid Jet XES
CISSY 
PhD K. F. Hodeck  HZB 
UE112_PGM-1 UE112  PGM  20 eV-700 eV VARIABLE  Liquid Jet XES  Prof. Dr. G. Schiwietz  HZB 
UE112_PGM-2a UE112  PGM 2  4 eV-200 eV LINEAR ANY ANGLE / CIRCULAR  n.a.  A. Rienks  HZB 
UE112_PGM-2b UE112  PGM 2  4 eV-200 eV LINEAR ANY ANGLE / CIRCULAR  One-Cubed ARPES  Dr. A. Varykhalov  HZB 
MX_BEAMLINE_14.1 7T-WLS-2  KMC-1  5000 eV-15500 eV HORIZONTAL  MX-14-1  Dr. U. Mueller  HZB 
MX_BEAMLINE_14.2 7T-WLS-2  KMC-2  5000 eV-15500 eV HORIZONTAL  MX-14-2  Dr K. S. Paithankar  FU-Berlin/HZB 
MX_BEAMLINE_14.3 7T-WLS-2  KMC-3  13.87 eV-13.87 eV HORIZONTAL  MX-14-3  Dr. M. S. Weiss  FU-Berlin/HZB 
U49-2_PGM-1 U49-2  PGM-1  85 eV-1600 eV HORIZONTAL  ISISS
PHOENEXS
LIQUIDROME
Liquid Jet XES
SAMIC-ASAM 
M. Vogel
.  
HZB 
U49-2_PGM-2 U49-2  PGM-2  86 eV-1890 eV HORIZONTAL  ISISS
LIQUIDROME
SAMIC-ASAM 
D. Friedrich  BTU Cottbus